The NHN Cloud Network service uses the IaaS token for authentication/authorization when making API calls. The IaaS token is the authentication token used by the NHN Cloud's OpenStack-based infrastructure service (IaaS). For more information on IaaS token issuance and usage, see IaaS token.
The logger and logging port API uses the network type endpoint. To see the exact endpoint, refer to serviceCatalog of the token issuance response.
| Type | Region | Endpoint |
|---|---|---|
| network | Korea (Pangyo) region Korea (Pyeongchon) region Korea (Gwangju) region |
https://kr1-api-network-infrastructure.nhncloudservice.com https://kr2-api-network-infrastructure.nhncloudservice.com https://kr3-api-network-infrastructure.nhncloudservice.com |
API response may show the fields not specified by the guide. These fields are internally used by NHN Cloud, and not used because they are subject to change without prior notice.
GET /v2.0/flowlog-loggers
X-Auth-Token: {tokenId}
This API does not require a request body.
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| id | Query | UUID | - | Flow Log Logger ID to query |
| name | Query | String | - | Flow Log logger name to query |
| resource_type | Query | String | - | Resource type of the Flow Log logger to query |
| resource_id | Query | String | - | Resource ID of the Flow Log logger to query |
| filter | Query | String | - | Filter of the Flow Log logger to query |
| aggregation_interval | Query | Integer | - | Aggregation interval of the Flow Log logger to query |
| storage_type | Query | String | - | Storage type of the Flow Log logger to query |
| log_format | Query | String | - | Log format of the Flow Log logger to query |
| compression_type | Query | String | - | Compression type of the Flow Log logger to query |
| partitioned_period | Query | String | - | Partition period of the Flow Log logger to query |
| customized_file_name | Query | String | - | File name format of the Flow Log logger to query |
| status | Query | String | - | Status of the Flow Log logger to query |
| Name | Type | Format | Description |
|---|---|---|---|
| flowlog_loggers | Body | Array | Flow Log object list |
| flowlog_loggers.name | Body | String | Flow Log logger name |
| flowlog_loggers.resource_type | Body | String | The target resource type of the Flow Log logger. One of the VPC, SUBNET, or PORT. |
| flowlog_loggers.resource_id | Body | UUID | Flow Log logger's target resource ID |
| flowlog_loggers.filter | Body | String | Filter to collect in Flow Log logger. One of the ALL, ACCEPT, or DROP. * ACCEPT captures only packets that are allowed to communicate* DROP captures only packets that are blocked to communicate* ALL captures both allowed and blocked packets |
| flowlog_loggers.aggregation_interval | Body | Integer | The interval at which data collected by the Flow Log logger is aggregated and written as a file to the storage. The unit is minutes. Files are created in the storage at this interval. |
| flowlog_loggers.connection_setup_only | Body | Boolean | If the value is true, only the packets attempting to establish the connection are collected. Setting this to true limits the collection targets as follows:* For TCP, packets are no longer collected when the TCP state is established * For UDP/ICMP, response packets are not collected |
| flowlog_loggers.storage_type | Body | String | The storage type of the Flow Log logger. Currently, only OBS is supported. |
| flowlog_loggers.storage_url | Body | String | Storage address of the Flow Log logger |
| flowlog_loggers.log_format | Body | String | The file format that the Flow Log logger will store. The file format can be CSV or PARQUET. |
| flowlog_loggers.compression_type | Body | String | Compression format of files stored by the Flow Log logger. Compressed formats RAW and GZIP are available. |
| flowlog_loggers.customized_field | Body | String | Field that the Flow Log logger will write to a file. * For the fields supported by Flow Log, see the Fields section under Statistical Information in the Flow Log Overview of the user guide. |
| flowlog_loggers.partition_period | Body | String | Refers to the folder creation structure when the Flow Log logger stores files in the storage. Supports HOUR and DAY. * If you specify DAY, a folder #{year}/#{month}/#{day} is created under the directory-path of storage_url entered by the user to separate the day* If you specify HOUR, a folder up to #{year}/#{month}/#{day}/#{hour} is created under the directory-path of storage_url entered by the user and separated by time * For other custom formats, the time is entered in #{year}, #{month}, #{day}, and #{hour}. |
| flowlog_loggers.customized_file_name | Body | String | The format of the file title when the Flow Log logger stores a file in a storage. * The default value is #{logger_id}_#{year}-#{month}-#{day}T#{hour}:#{minute}:#{second}KST |
| flowlog_loggers.admin_state_up | Body | Boolean | The enabled status of the Flow Log logger. If false, it is disabled and not collected. |
| flowlog_loggers.description | Body | String | Description of the Flow Log logger |
| flowlog_loggers.status | Body | Enum | Status of the Flow Log logger |
| flowlog_loggers.created_at | Body | Date | Time the Flow Log logger was created |
| flowlog_loggers.updated_at | Body | Date | Time the Flow Log logger was modified |
| flowlog_loggers.error_type | Body | String | If an error occurs in the Flow Log logger, the reason for the error is displayed. For more information, see the error types at the bottom of the page. |
{
"flowlog_loggers": [
{
"status": "ACTIVE",
"connection_setup_only": false,
"description": "",
"partition_period": "DAY",
"resource_id": "12799b52-0c81-4820-8fe6-b4963989ffe1",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-07-29 09:21:09",
"error_type": "",
"updated_at": "2024-08-04 05:11:05",
"customized_field": "timestamp_start,timestamp_end,interface_id,vm_id,subnet_id,vpc_id,region,protocol,src_addr,dst_addr,src_port,dst_port,tcp_flag,packets,bytes,filter,status",
"id": "3e84619a-1e49-4b19-b353-a15f7d278f94",
"filter": "ACCEPT",
"storage_type": "OBS",
"aggregation_interval": 10,
"admin_state_up": true,
"log_format": "CSV",
"storage_url": "https://kr2-api-object-storage.alpha-nhncloudservice.com/v1/AUTH_e670167936434f85a03694184000ffe6/flowlog-test/240729",
"project_id": "419a823563124dc5b5627f5e79db8174",
"compression_type": "RAW",
"resource_type": "PORT",
"name": "test"
},
{
"status": "ACTIVE",
"connection_setup_only": false,
"description": "KR2test",
"partition_period": "HOUR",
"resource_id": "045e204c-4624-4b68-ac8a-7375989d3b79",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-08-04 05:17:03",
"error_type": "",
"updated_at": "2024-08-04 05:19:04",
"customized_field": "timestamp_start,timestamp_end,interface_id,vm_id,subnet_id,vpc_id,region,protocol,src_addr,dst_addr,src_port,dst_port,tcp_flag,packets,bytes,filter,status",
"id": "4a9912b9-7bbc-48f0-b066-fc165486f49d",
"filter": "ALL",
"storage_type": "OBS",
"aggregation_interval": 1,
"admin_state_up": true,
"log_format": "CSV",
"storage_url": "https://kr2-api-object-storage.alpha-nhncloudservice.com/v1/AUTH_e670167936434f85a03694184000ffe6/flowlog-test/240729",
"project_id": "419a823563124dc5b5627f5e79db8174",
"compression_type": "RAW",
"resource_type": "PORT",
"name": "flowlog-create-test"
}
]
}
GET /v2.0/flowlog-loggers/{flowlogLoggerId}
X-Auth-Token: {tokenId}
This API does not require a request body.
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| flowlogLoggerId | URL | UUID | O | Flow Log logger ID |
| Name | Type | Format | Description |
|---|---|---|---|
| flowlog_logger | Body | Object | Flow Log logger information object |
| flowlog_logger.name | Body | String | Flow Log logger name |
| flowlog_logger.resource_type | Body | String | The target resource type of the Flow Log logger. One of the VPC, SUBNET, or PORT. |
| flowlog_logger.resource_id | Body | UUID | Flow Log logger's target resource ID |
| flowlog_logger.filter | Body | String | Filter to collect in Flow Log logger. One of the ALL, ACCEPT, or DROP. * ACCEPT captures only packets that are allowed to communicate* DROP captures only packets that are blocked to communicate* ALL captures both allowed and blocked packets |
| flowlog_logger.aggregation_interval | Body | Integer | The interval at which data collected by the Flow Log logger is aggregated and written as a file to the storage. The unit is minutes. Files are created in the storage at this interval. |
| flowlog_logger.connection_setup_only | Body | Boolean | If the value is true, only the packets attempting to establish the connection are collected. Setting this to true limits the collection targets as follows:* For TCP, packets are no longer collected when the TCP state is established * For UDP/ICMP, response packets are not collected |
| flowlog_logger.storage_type | Body | String | The storage type of the Flow Log logger. Currently, only OBS is supported. |
| flowlog_logger.storage_url | Body | String | Storage address of the Flow Log logger |
| flowlog_logger.log_format | Body | String | The file format that the Flow Log logger will store. The file format can be CSV or PARQUET. |
| flowlog_logger.compression_type | Body | String | Compression format of files stored by the Flow Log logger. Compressed formats RAW and GZIP are available. |
| flowlog_logger.customized_field | Body | String | Field that the Flow Log logger will write to a file. * For the fields supported by Flow Log, see the Fields section under Statistical Information in the Flow Log Overview of the user guide. |
| flowlog_logger.partition_period | Body | String | Refers to the folder creation structure when the Flow Log logger stores files in the storage. Supports HOUR and DAY. * If you specify DAY, a folder #{year}/#{month}/#{day} is created under the directory-path of storage_url entered by the user to separate the day* If you specify HOUR, a folder up to #{year}/#{month}/#{day}/#{hour} is created under the directory-path of storage_url entered by the user and separated by time * For other custom formats, the time is entered in #{year}, #{month}, #{day}, and #{hour}. |
| flowlog_logger.customized_file_name | Body | String | The format of the file title when the Flow Log logger stores a file in a storage. * The default value is #{logger_id}_#{year}-#{month}-#{day}T#{hour}:#{minute}:#{second}KST |
| flowlog_logger.admin_state_up | Body | Boolean | The enabled status of the Flow Log logger. If false, it is disabled and not collected. |
| flowlog_logger.description | Body | String | Description of the Flow Log logger |
| flowlog_logger.status | Body | Enum | Status of the Flow Log logger |
| flowlog_logger.created_at | Body | Date | Time the Flow Log logger was created |
| flowlog_logger.updated_at | Body | Date | Time the Flow Log logger was modified |
| flowlog_logger.error_type | Body | String | If an error occurs in the Flow Log logger, the reason for the error is displayed. For more information, see the error types at the bottom of the page. |
{
"flowlog_logger": {
"status": "ACTIVE",
"connection_setup_only": false,
"description": "flowlog-create-description",
"partition_period": "HOUR",
"resource_id": "045e204c-4624-4b68-ac8a-7375989d3b79",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-08-04 05:22:57",
"error_type": "",
"updated_at": "2024-08-04 05:22:59",
"customized_field": "timestamp_start,timestamp_end,interface_id,vm_id,subnet_id,vpc_id,region,protocol,src_addr,dst_addr,src_port,dst_port,tcp_flag,packets,bytes,filter,status",
"id": "8287f6df-42cb-4cb6-a3f3-0e13fad43526",
"filter": "ALL",
"storage_type": "OBS",
"aggregation_interval": 1,
"admin_state_up": true,
"log_format": "CSV",
"storage_url": "https://kr2-api-object-storage.alpha-nhncloudservice.com/v1/AUTH_e670167936434f85a03694184000ffe6/flowlog-test/240729",
"project_id": "419a823563124dc5b5627f5e79db8174",
"compression_type": "RAW",
"resource_type": "PORT",
"name": "flowlog-create-test"
}
}
POST /v2.0/flowlog-loggers
X-Auth-Token: {tokenId}
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| flowlog_logger | Body | Object | O | Flow Log logger information object |
| flowlog_logger.name | Body | String | O | Flow Log logger name |
| flowlog_logger.resource_type | Body | String | The target resource type of the Flow Log logger. One of the VPC, SUBNET, or PORT. If not entered, it is considered to be PORT. |
|
| flowlog_logger.resource_id | Body | UUID | O | Flow Log logger's target resource ID |
| flowlog_logger.filter | Body | String | Filter to collect in Flow Log logger. One of the ALL, ACCEPT, or DROP. The default value is ALL.* ACCEPT captures only packets that are allowed to communicate* DROP captures only packets that are blocked to communicate* ALL captures both allowed and blocked packets |
|
| flowlog_logger.aggregation_interval | Body | Integer | The interval at which data collected by the Flow Log logger is aggregated and written as a file to the storage. The unit is minutes. Files are created in the storage at this interval. The default is 10 minutes. | |
| flowlog_logger.connection_setup_only | Body | Boolean | If the value is true, only the packets attempting to establish the connection are collected. If set to true, the collection target is limited as follows. The default value is false* For TCP, packets are no longer collected when the TCP state is established * For UDP/ICMP, response packets are not collected |
|
| flowlog_logger.storage_type | Body | String | O | The storage type of the Flow Log logger. Currently, only OBS is supported. |
| flowlog_logger.storage_url | Body | String | O | The storage address of the Flow Log logger. If the storage type is OBS, you must enter all https://{object-storage-endpoint}/{AUTH-id}/{container}/{directory-path}. |
| flowlog_logger.log_format | Body | String | The file format that the Flow Log logger will store. The file format can be CSV and PARQUET. The default value is CSV. |
|
| flowlog_logger.compression_type | Body | String | Compression format of files stored by the Flow Log logger. Compressed formats RAW and GZIP are available. The default is RAW. |
|
| flowlog_logger.customized_field | Body | String | Fields that the Flow Log logger records in a file. * It must be written in the form of commas, as shown in the example below. * For the fields supported by Flow Log, see the Fields section under Statistical Information in the Flow Log Overview of the user guide. |
|
| flowlog_logger.partition_period | Body | String | Refers to the folder creation structure when the Flow Log logger stores files in the storage. Supports HOUR and DAY. * If you specify DAY, a folder #{year}/#{month}/#{day} is created under the directory-path of storage_url entered by the user to separate the day* If you specify HOUR, a folder up to #{year}/#{month}/#{day}/#{hour} is created under the directory-path of storage_url entered by the user and separated by time * For other custom formats, the time is entered in #{year}, #{month}, #{day}, and #{hour}. * Custom format only allows input of numbers, English characters, and some special characters (/, -, _, =). Enter / to separate folders. * (e.g., enter year=#{year}/month=#{month}/day=#{day}) and store Flow Log files for September 1, 2024 under the folder year=2024/month=09/day=01 |
|
| flowlog_logger.customized_file_name | Body | String | The format of the file title when the Flow Log logger stores a file in a storage. * The default value is #{logger_id}_#{year}-#{month}-#{day}T#{hour}:#{minute}:#{second}KST * You can define the title of Flow Log logger file by using the template variables #{logger_id}, #{year}, #{month}, #{day}, #{hour}, #{minute}, and #{second}, respectively, precisely once and for each. |
|
| flowlog_logger.admin_state_up | Body | Boolean | Enabled status of the Flow Log logger. If false, it is disabled and not collected. The default value is true. |
|
| flowlog_logger.description | Body | String | Description of the Flow Log logger |
{
"flowlog_logger": {
"name": "flowlog-create-test",
"resource_type": "PORT",
"resource_id": "045e204c-4624-4b68-ac8a-7375989d3b79",
"filter": "ALL",
"aggregation_interval": 1,
"connection_setup_only": false,
"storage_type": "OBS",
"storage_url": "https://kr2-api-object-storage.alpha-nhncloudservice.com/v1/AUTH_e670167936434f85a03694184000ffe6/flowlog-test/240729",
"log_format": "CSV",
"compression_type": "RAW",
"customized_field": "timestamp_start,timestamp_end,interface_id,vm_id,subnet_id,vpc_id,region,protocol,src_addr,dst_addr,src_port,dst_port,tcp_flag,packets,bytes,filter,status",
"partition_period": "HOUR",
"admin_state_up": true,
"description": "KR2 alpha cloud trail test"
}
}
| Name | Type | Format | Description |
|---|---|---|---|
| flowlog_logger | Body | Object | Flow Log logger information object |
| flowlog_logger.name | Body | String | Flow Log logger name |
| flowlog_logger.resource_type | Body | String | The target resource type of the Flow Log logger. One of the VPC, SUBNET, or PORT. |
| flowlog_logger.resource_id | Body | UUID | Flow Log logger's target resource ID |
| flowlog_logger.filter | Body | String | Filter to collect in Flow Log logger. One of the ALL, ACCEPT, or DROP. * ACCEPT captures only packets that are allowed to communicate* DROP captures only packets that are blocked to communicate* ALL captures both allowed and blocked packets |
| flowlog_logger.aggregation_interval | Body | Integer | The interval at which data collected by the Flow Log logger is aggregated and written as a file to the storage. The unit is minutes. Files are created in the storage at this interval. |
| flowlog_logger.connection_setup_only | Body | Boolean | If the value is true, only the packets attempting to establish the connection are collected. Setting this to true limits the collection targets as follows:* For TCP, packets are no longer collected when the TCP state is established * For UDP/ICMP, response packets are not collected |
| flowlog_logger.storage_type | Body | String | The storage type of the Flow Log logger. Currently, only OBS is supported. |
| flowlog_logger.storage_url | Body | String | Storage address of the Flow Log logger |
| flowlog_logger.log_format | Body | String | The file format that the Flow Log logger will store. The file format can be CSV or PARQUET. |
| flowlog_logger.compression_type | Body | String | Compression format of files stored by the Flow Log logger. Compressed formats RAW and GZIP are available. |
| flowlog_logger.customized_field | Body | String | Field that the Flow Log logger will write to a file. * For the fields supported by Flow Log, see the Fields section under Statistical Information in the Flow Log Overview of the user guide. |
| flowlog_logger.partition_period | Body | String | Refers to the folder creation structure when the Flow Log logger stores files in the storage. Supports HOUR and DAY. * If you specify DAY, a folder #{year}/#{month}/#{day} is created under the directory-path of storage_url entered by the user to separate the day* If you specify HOUR, a folder up to #{year}/#{month}/#{day}/#{hour} is created under the directory-path of storage_url entered by the user and separated by time * For other custom formats, the time is entered in #{year}, #{month}, #{day}, and #{hour}. |
| flowlog_logger.customized_file_name | Body | String | The format of the file title when the Flow Log logger stores a file in a storage. * The default value is #{logger_id}_#{year}-#{month}-#{day}T#{hour}:#{minute}:#{second}KST |
| flowlog_logger.admin_state_up | Body | Boolean | The enabled status of the Flow Log logger. If false, it is disabled and not collected. |
| flowlog_logger.description | Body | String | Description of the Flow Log logger |
| flowlog_logger.status | Body | Enum | Status of the Flow Log logger |
| flowlog_logger.created_at | Body | Date | Time the Flow Log logger was created |
| flowlog_logger.updated_at | Body | Date | Time the Flow Log logger was modified |
| flowlog_logger.error_type | Body | String | If an error occurs in the Flow Log logger, the reason for the error is displayed. For more information, see the error types at the bottom of the page. |
{
"flowlog_logger": {
"status": "BUILD",
"connection_setup_only": false,
"description": "KR2 alpha cloud trail test",
"partition_period": "HOUR",
"resource_id": "045e204c-4624-4b68-ac8a-7375989d3b79",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-08-04 04:46:33",
"error_type": "",
"updated_at": "2024-08-04 04:46:33",
"customized_field": "timestamp_start,timestamp_end,interface_id,vm_id,subnet_id,vpc_id,region,protocol,src_addr,dst_addr,src_port,dst_port,tcp_flag,packets,bytes,filter,status",
"id": "08288f3c-d535-4343-9998-8d1d76a5c8a1",
"filter": "ALL",
"storage_type": "OBS",
"aggregation_interval": 1,
"admin_state_up": true,
"log_format": "CSV",
"storage_url": "https://kr2-api-object-storage.alpha-nhncloudservice.com/v1/AUTH_e670167936434f85a03694184000ffe6/flowlog-test/240729",
"project_id": "419a823563124dc5b5627f5e79db8174",
"compression_type": "RAW",
"resource_type": "PORT",
"name": "flowlog-create-test"
}
}
PUT /v2.0/flowlog-loggers/{flowlogLoggerId}
X-Auth-Token: {tokenId}
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| flowlogLoggerId | URL | UUID | O | Flow Log logger ID |
| flowlog_logger | Body | Object | O | Flow Log logger information object |
| flowlog_logger.name | Body | String | O | Flow Log logger name |
| flowlog_logger.admin_state_up | Body | Boolean | Enabled status of the Flow Log logger. If false, it is disabled and not collected. The default value is true. |
|
| flowlog_logger.description | Body | String | Description of the Flow Log logger |
{
"flowlog_logger": {
"name": "flowlog-name-updated",
"description": "flowlog-description-updated",
"admin_state_up": false
}
}
| Name | Type | Format | Description |
|---|---|---|---|
| flowlog_logger | Body | Object | Flow Log logger information object |
| flowlog_logger.name | Body | String | Flow Log logger name |
| flowlog_logger.resource_type | Body | String | The target resource type of the Flow Log logger. One of the VPC, SUBNET, or PORT. |
| flowlog_logger.resource_id | Body | UUID | Flow Log logger's target resource ID |
| flowlog_logger.filter | Body | String | Filter to collect in Flow Log logger. One of the ALL, ACCEPT, or DROP. * ACCEPT captures only packets that are allowed to communicate* DROP captures only packets that are blocked to communicate* ALL captures both allowed and blocked packets |
| flowlog_logger.aggregation_interval | Body | Integer | The interval at which data collected by the Flow Log logger is aggregated and written as a file to the storage. The unit is minutes. Files are created in the storage at this interval. |
| flowlog_logger.connection_setup_only | Body | Boolean | If the value is true, only the packets attempting to establish the connection are collected. Setting this to true limits the collection targets as follows:* For TCP, packets are no longer collected when the TCP state is established * For UDP/ICMP, response packets are not collected |
| flowlog_logger.storage_type | Body | String | The storage type of the Flow Log logger. Currently, only OBS is supported. |
| flowlog_logger.storage_url | Body | String | Storage address of the Flow Log logger |
| flowlog_logger.log_format | Body | String | The file format that the Flow Log logger will store. The file format can be CSV or PARQUET. |
| flowlog_logger.compression_type | Body | String | Compression format of files stored by the Flow Log logger. Compressed formats RAW and GZIP are available. |
| flowlog_logger.customized_field | Body | String | Fields that the Flow Log logger records in a file. This feature is not currently supported. * For the fields supported by Flow Log, see the Fields section under Statistical Information in the Flow Log Overview of the user guide. |
| flowlog_logger.partition_period | Body | String | Refers to the folder creation structure when the Flow Log logger stores files in the storage. Supports HOUR and DAY. * If you specify DAY, a folder #{year}/#{month}/#{day} is created under the directory-path of storage_url entered by the user to separate the day* If you specify HOUR, a folder up to #{year}/#{month}/#{day}/#{hour} is created under the directory-path of storage_url entered by the user and separated by time * For other custom formats, the time is entered in #{year}, #{month}, #{day}, and #{hour}. |
| flowlog_logger.customized_file_name | Body | String | The format of the file title when the Flow Log logger stores a file in a storage. * The default value is #{logger_id}_#{year}-#{month}-#{day}T#{hour}:#{minute}:#{second}KST |
| flowlog_logger.admin_state_up | Body | Boolean | The enabled status of the Flow Log logger. If false, it is disabled and not collected. |
| flowlog_logger.description | Body | String | Description of the Flow Log logger |
| flowlog_logger.status | Body | Enum | Status of the Flow Log logger |
| flowlog_logger.created_at | Body | Date | Time the Flow Log logger was created |
| flowlog_logger.updated_at | Body | Date | Time the Flow Log logger was modified |
| flowlog_logger.error_type | Body | String | If an error occurs in the Flow Log logger, the reason for the error is displayed. For more information, see the error types at the bottom of the page. |
{
"flowlog_logger": {
"status": "INACTIVE",
"connection_setup_only": false,
"description": "flowlog-description-updated",
"partition_period": "HOUR",
"resource_id": "045e204c-4624-4b68-ac8a-7375989d3b79",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-08-04 05:22:57",
"error_type": "",
"updated_at": "2024-08-04 05:27:35.226363",
"customized_field": "timestamp_start,timestamp_end,interface_id,vm_id,subnet_id,vpc_id,region,protocol,src_addr,dst_addr,src_port,dst_port,tcp_flag,packets,bytes,filter,status",
"id": "8287f6df-42cb-4cb6-a3f3-0e13fad43526",
"filter": "ALL",
"storage_type": "OBS",
"aggregation_interval": 1,
"admin_state_up": false,
"log_format": "CSV",
"storage_url": "https://kr2-api-object-storage.alpha-nhncloudservice.com/v1/AUTH_e670167936434f85a03694184000ffe6/flowlog-test/240729",
"project_id": "419a823563124dc5b5627f5e79db8174",
"compression_type": "RAW",
"resource_type": "PORT",
"name": "flowlog-name-updated"
}
}
DELETE /v2.0/flowlog-loggers/{flowlogLoggerId}
X-Auth-Token: {tokenId}
This API does not require a request body.
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| flowlogLoggerId | URL | UUID | O | Flow Log logger ID |
This API does not return a response body.
GET /v2.0/flowlog-logging-ports
X-Auth-Token: {tokenId}
This API does not require a request body.
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| id | Query | UUID | - | ID of the Flow Log logging port to query |
| logger_id | Query | UUID | - | Logger ID of the Flow Log logging port to query |
| port_id | Query | UUID | - | ID of port of the Flow Log logging port to query |
| network_id | Query | UUID | - | VPC ID of the Flow Log to query |
| Name | Type | Format | Description |
|---|---|---|---|
| flowlog_logging_ports | Body | Array | Flow Log logging object list |
| flowlog_logging_ports.id | Body | UUID | Flow Log logging port ID |
| flowlog_logging_ports.logger_id | Body | UUID | ID of the Flow Log logger to which the Flow Log logging port belongs |
| flowlog_logging_ports.port_id | Body | UUID | ID of port being logged |
| flowlog_logging_ports.network_id | Body | UUID | Network ID |
| flowlog_logging_ports.created_at | Body | Date | Time the Flow Log logging port was created |
| flowlog_logging_ports.updated_at | Body | Date | Time the Flow Log logging port was modified |
{
"flowlog_logging_ports": [
{
"network_id": "0afbf332-3432-450f-a25a-3cfa56b886d9",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-07-29 09:21:09",
"updated_at": "2024-07-29 09:21:09",
"logger_id": "3e84619a-1e49-4b19-b353-a15f7d278f94",
"project_id": "419a823563124dc5b5627f5e79db8174",
"port_id": "12799b52-0c81-4820-8fe6-b4963989ffe1",
"id": "6e97b87a-21ac-42d2-afc7-6d180ba93417"
},
{
"network_id": "0afbf332-3432-450f-a25a-3cfa56b886d9",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-08-04 05:22:57",
"updated_at": "2024-08-04 05:22:57",
"logger_id": "8287f6df-42cb-4cb6-a3f3-0e13fad43526",
"project_id": "419a823563124dc5b5627f5e79db8174",
"port_id": "045e204c-4624-4b68-ac8a-7375989d3b79",
"id": "bb036e03-ce55-48d0-aea3-685bfbee24d0"
}
]
}
GET /v2.0/flowlog-logging-ports/{flowlogLoggingPortId}
X-Auth-Token: {tokenId}
This API does not require a request body.
| Name | Type | Format | Required | Description |
|---|---|---|---|---|
| tokenId | Header | String | O | Token ID |
| flowlogLoggingPortId | URL | UUID | O | Flow Log logging port ID |
| Name | Type | Format | Description |
|---|---|---|---|
| flowlog_logging_port | Body | Object | Flow Log logging object |
| flowlog_logging_port.id | Body | UUID | Flow Log logging port ID |
| flowlog_logging_port.logger_id | Body | UUID | ID of the Flow Log logger to which the Flow Log logging port belongs |
| flowlog_logging_port.port_id | Body | UUID | ID of port being logged |
| flowlog_logging_port.network_id | Body | UUID | Network ID |
| flowlog_logging_port.created_at | Body | Date | Time the Flow Log logging port was created |
| flowlog_logging_port.updated_at | Body | Date | Time the Flow Log logging port was modified |
{
"flowlog_logging_port": {
"network_id": "0afbf332-3432-450f-a25a-3cfa56b886d9",
"tenant_id": "419a823563124dc5b5627f5e79db8174",
"created_at": "2024-07-29 09:21:09",
"updated_at": "2024-07-29 09:21:09",
"logger_id": "3e84619a-1e49-4b19-b353-a15f7d278f94",
"project_id": "419a823563124dc5b5627f5e79db8174",
"port_id": "12799b52-0c81-4820-8fe6-b4963989ffe1",
"id": "6e97b87a-21ac-42d2-afc7-6d180ba93417"
}
}
If the environment to use Flow Log is not configured correctly, an error may occur. In this case, you can look up flowlog_logger.error_type to find the cause of the error.
The status and error types of Flow Log loggers are as follows:
| Flow Log logger status | Error Type | Error cause | Action required |
|---|---|---|---|
| ACTIVE | - | - | - |
| BUILD | - | - | - |
| ERROR | AuthenticationSystemError | There's a problem with the authentication system. Please contact Customer Support. | Flow Log system account has not received a token issued from the Keystone server. |
| ERROR | OBSConfigurationError | Check the OBS URL and access policy. | Dummy data was sent to the user's storage, but a 403 error occurred due to insufficient OBS access permissions. Check the container URL and access policy. |
| ERROR | OBSServiceNotAvailableError | The OBS service is not working. Please contact Customer Support. | Dummy data was sent to the user's storage, but an error other than 401 or 403 occurred. |